According to Highway Transportation Statistics (2025), published by Türkiye's General Directorate of Highways (Karayolları Genel Müdürlüğü, KGM), Türkiye had 3,796 km of motorways (tolled, access-controlled highways) at the end of 2025. KGM operates some of these roads; private operators run the rest under public-private partnership contracts such as build-operate-transfer. Who owns and answers for the central systems depends on the contract.
SCADA, variable message signs, cameras, and toll systems usually come from different manufacturers. The network they run on, the central servers, and the security layer often sit where nobody fully owns them. ARGE ICT builds and operates that layer, and also manages the servers, databases, and licenses of SCADA systems.
Systems on a motorway and in a tunnel
The Ministry of Transport and Infrastructure calls these systems intelligent transportation systems (ITS). In the field and at the center you will find:
- Control center. This is where operators watch the road and the tunnel and manage the response to an incident. KGM calls it the "tunnel control center" for tunnels, and one center can monitor several tunnels.
- SCADA. The supervisory control and data acquisition (SCADA) system brings a tunnel's ventilation, lighting, fire detection, and power systems onto the operator's screen. Programmable logic controllers (PLCs) in the field carry out the commands.
- Camera monitoring and incident detection. Cameras watch the road, and incident detection cameras and software detect traffic incidents automatically.
- Variable message signs (VMS) and variable traffic signs. They show drivers messages and lane information from the control center.
- SOS call boxes. These emergency phones let a driver talk to the control center.
- Weather stations and ice detection. They report the weather and road surface conditions to the center.
- License plate recognition. It reads the plate of each passing vehicle. A plate counts as personal data, so the recording and retention rules get their own section below.
- Video wall and monitoring screens. In the control center they show camera feeds and SCADA screens to the operator.
In tunnels, jet fans, gas and visibility measurement, fire detection, and emergency announcement systems join the list. Toll collection and free-flow systems connect to the same network and the same center. The software, the devices, and the field installation come from different companies, and all of them need a network.
Division of responsibility
The system manufacturer and the field integrator write and commission the SCADA software, the PLC programs, and the tunnel safety scenarios (ventilation, fire, closure). KGM's tunnel maintenance scheme also assigns PLC and SCADA software faults to the manufacturer. ARGE ICT does not develop that software; we manage the servers, databases, licenses, and monitoring that SCADA systems run on, and we build the network they connect to, the central infrastructure, and the security.
| Work | Who does it |
|---|---|
| SCADA software, PLC programs, tunnel safety scenarios | System manufacturer and field integrator |
| VMS, SOS, sensors, weather stations, and toll collection hardware and software | Device manufacturer and field integrator |
| Procurement, installation, and maintenance of cameras, monitoring screens, network and server hardware, and licenses | ARGE ICT (poles, brackets, and cabling stay with the field contractor) |
| Network design: ring topology, VLANs, routing, firewall rules; industrial switch procurement and installation | ARGE ICT |
| Control center infrastructure: servers, storage, virtualization, backup, disaster recovery | ARGE ICT |
| Operating SCADA systems: servers, virtualization, databases, clusters, licenses, monitoring, and backup | ARGE ICT |
| Manufacturer maintenance access, device monitoring, log collection | ARGE ICT |
| Deciding the video retention period, personal data assessment | The operator (data controller) |
An industrial network on the fiber backbone
On motorway projects, fiber runs along the road as one or more backbones, and the control center, tunnel equipment rooms, and field cabinets connect to it. We design the network as a ring. If a link or a switch in the ring fails, traffic flows around the other side. Recovery time depends on the switch's redundancy protocol and the number of devices in the ring; we test the value the manufacturer gives during commissioning.
A device in a cabinet, a tunnel, or beside the road does not sit in an office. Temperatures swing, and there is vibration, dust, and electrical noise. That is why we choose industrial switches instead of office-grade ones. We look at:
- A wide operating temperature range and fanless cooling.
- DIN rail mounting in the cabinet.
- The PoE (power over Ethernet) budget for cameras and access points.
- Ring redundancy protocols and a management interface (SNMP).
- Time synchronization: NTP for general records, PTP where precision is needed.
- Environmental standards: EN 50121-4 for railway electromagnetic compatibility, NEMA TS2 for traffic control equipment, and IEC 61850-3 for power utility environments.
These standards are not mandatory for motorways in Türkiye; they indicate how well a device tolerates its environment. We confirm in the model's data sheet which one your specification calls for. Time synchronization matters for one reason: if camera recordings, SCADA alarms, and security logs do not show the same time after an incident, it is hard to reconstruct the sequence of events.
Control center and backup center
Behind the control center is a server room: SCADA and video management servers, storage, UPS, climate control, and the network. We virtualize the servers and put critical ones in a two-server high availability (HA) cluster. We calculate the power needs of the servers and network devices in the server room and monitor the UPS. Generators and the tunnel's emergency power supply belong to the electrical contractor.
We procure, install, and configure the hardware of the video wall and monitoring screens. Integrating the wall controller with the SCADA or video software is the software manufacturer's job. The European Union directive behind the control center and video monitoring requirements in tunnels (2004/54/EC) is covered in the Regulations section.
If the main center goes out of service, a backup control center or a second server room takes over. In a suitable design, the backup environment can also be built on ARGE Cloud, our own infrastructure running in a data center in Istanbul, which gives you a dedicated VPC (virtual private cloud). Whether the SCADA software may run in a backup environment depends on its license and support terms; we confirm this with the manufacturer beforehand.
Managing SCADA systems
We manage the IT side on which the SCADA software runs: the SCADA servers and the virtualization layer, the operating system, the SCADA and historian databases, high availability clusters, user accounts, and monitoring. We also look after database backups, maintenance, and performance. We track and renew the SCADA, operating system, database, and virtualization licenses; we keep the end dates in one record and plan renewals before they expire.
We apply updates and patches only in versions the manufacturer has approved, and within a planned maintenance window. Developing the SCADA software, programming PLCs, and writing tunnel safety scenarios is the manufacturer's job. When a fault occurs, we work together with the manufacturer and give it recorded, restricted access.
- Server, virtualization, and operating system management
- SCADA and historian database management: backup, maintenance, performance
- High availability clusters
- License tracking and renewal
- User accounts and monitoring
Video recording, archive, and retention
The size of the recording storage is the number of cameras times the bit rate per camera times the retention days. The bit rate changes with resolution, compression format (codec), and motion in the scene, so we do not quote a fixed figure; we do the calculation with your camera list. Primary recording stays at the center or in regional centers, because carrying the continuous streams of hundreds of cameras to the cloud takes a lot of bandwidth. The second copy of incident videos and the long-term archive goes to the isolated backup zone on ARGE Cloud.
Camera footage and license plates are personal data under KVKK, Türkiye's Personal Data Protection Law (Law No. 6698). Law No. 6698 does not set a fixed retention period for camera recordings. The test in the Personal Data Protection Authority's public announcement on security cameras is this: a recording stays limited to its purpose, is kept only as long as the purpose requires, is deleted when the reason ends, and only authorized people may access it. The people filmed also need to be informed. If your contract or the authority's specification sets a period, that period applies.
The operator, as data controller, decides the period. We apply the decision in the infrastructure: per-person access rights, recording encryption, an access log, and automatic deletion when the period ends.
Where each component runs
Real-time control runs in the field and at the center; we use the cloud for reporting, security information and event management (SIEM), backup, and the archive copy. There are three reasons: the tunnel scenario has to keep running in the field even when the link to the center drops, camera streams need a lot of bandwidth, and operator screens and camera control need low latency.
| Component | Where it should run | Short reason |
|---|---|---|
| Tunnel PLCs and safety scenarios | In the field | Must keep working if the link to the center drops |
| SCADA servers | In the control center, two servers | Operator screens do not tolerate delay |
| SCADA backup environment | Backup center or ARGE Cloud (with manufacturer approval) | If the main center building goes out of service |
| Camera recording (primary) | Center or regional center | Carrying hundreds of streams to the cloud takes bandwidth |
| Incident video and archive copy | ARGE Cloud isolated backup zone | A copy kept apart from the systems ransomware could reach |
| Reporting and traffic data | ARGE Cloud or the center | Not sensitive to delay |
| Logs and SIEM | ARGE Cloud | Logs stay elsewhere even if a field site is compromised |
| Manufacturer maintenance access | ARGE ZTNA | Per-person, per-device, recorded access |
| Toll collection software | The environment the software owner specifies | Bank integration and contract terms decide |
We can build the same setup on-premises in your own server room, or as a hybrid of the two.
IT/OT separation and the IEC 62443 zones and conduits approach
Operational technology (OT) means the systems that control the physical process in the field: PLCs, SCADA, VMS. IT covers the office network, email, and user computers. Control systems often run for years without patches. That is why ransomware on an office computer must not be able to cross into the tunnel network.
We design this with the zones and conduits approach of the IEC 62443 series. A zone is a group of assets with similar risk: field cabinets, SCADA servers, the camera network, the office. A conduit is the permitted communication path between two zones. We put a firewall on each conduit and write rules that allow only the required protocols and addresses. If an old PLC has no security features of its own, a firewall in front of it is a compensating control that reduces that risk. We use the Purdue level model, familiar in the industry, only as a way to explain the layout.
We apply the standard's approach as a design method; this is not a certification claim.
Manufacturer maintenance access: ARGE ZTNA instead of a permanent VPN
SCADA and PLC manufacturers want to connect remotely for faults and updates. A permanent VPN account, once opened, usually gives the user access to the whole network, and over time it becomes unclear who is connecting.
ARGE ZTNA is the zero trust network access (ZTNA) product that ARGE ICT developed. It checks identity, device, and permission again on every connection. Two-step verification is mandatory, only a registered device can connect, and the user sees only the resource the administrator allows; a manufacturer can be given just the SCADA server, for example. Access credentials are short-lived and are revoked when a person or a firm leaves. Every session, device, and access decision is recorded, and a monthly report goes to the administrator. The product runs on your own firewall, and traffic does not pass through a third-party cloud. If privileged sessions need separate oversight, we add privileged access management (PAM) as well.
Monitoring and logs: from edge devices to the SIEM
We monitor field edge devices (cameras, switches, PLCs, sensors, the cabinet UPS) with a network management system (NMS) over SNMP, the simple network management protocol. What we watch is reachability: whether a device responds, whether a port is down, whether the ring switched to its backup path, whether the UPS is on battery. We raise alarms and agree with you who receives them. For a PLC we monitor reachability only; we do not touch the program.
We collect switch, firewall, and server logs in a SIEM system. If the logs are kept on ARGE Cloud, they stay elsewhere even if a field site is compromised. Monitoring hours and response scope are written in the contract.
Connecting the center, the regions, and the cloud
The center, regional centers, and tunnel equipment rooms connect over the fiber backbone. We extend the same structure to ARGE Cloud in two ways. If the carrier provides MPLS, a private line that does not touch the internet, we extend that line to the cloud. Without MPLS, we build IPsec tunnels over existing lines with SD-WAN-capable routers and firewalls; SD-WAN moves traffic to another line when one drops.
The carrier provides the line; we design, build, and monitor the network on top of it. For a comparison of the connection methods, see how head office, branches, and the cloud connect.
Regulations
This page does not give legal advice; your legal and compliance team assesses the items below. We take on the infrastructure share.
Cybersecurity Law No. 7545
The law was published in the Official Gazette on March 19, 2025, and covers organizations that provide services through information systems. Reporting the vulnerabilities and cyber incidents you detect to the Cybersecurity Presidency (Siber Güvenlik Başkanlığı) is one of these general duties. Critical infrastructure carries an extra rule: the law expects cybersecurity products and services used there to come from providers the Presidency has authorized. The Presidency's secondary regulations set how that authorization works; we confirm the current status with you at the proposal stage. Transportation is among the critical infrastructure sectors set by the Cybersecurity Board. The Presidency decides which individual operators count as critical infrastructure; we cannot make that determination.
Information and Communication Security Guide
The Guide rests on Presidential Circular No. 2019/12, published in the Official Gazette on July 6, 2019. The Circular covers public bodies and operators that provide critical infrastructure services; transportation is among the sectors the Guide lists. If you are in scope, we map the Guide's measures that touch infrastructure (network separation, access management, logging) with you.
KVKK
Camera and plate data call for notice, a retention period, authorized access, and technical measures. The video section of this page covers the infrastructure share.
Tunnel directive
2004/54/EC is a European Union directive, not Turkish law. KGM documents say road tunnels follow it. It lists equipment such as a control center and video monitoring for tunnels above certain thresholds. Designing for conformity with the directive is outside our scope.
Hardware, camera, and license procurement, installation, and maintenance
We are vendor-neutral and procure industrial switches, firewalls, servers, storage, cameras, monitoring screens, and licenses through single-source procurement. For the server and storage side, see server and storage. We do the rack mounting, configuration, and commissioning. We maintain the hardware we install under an IT maintenance agreement; scope and response hours are written in the contract.
We keep device warranty and maintenance terms in one calendar through warranty and maintenance tracking, and software and monitoring license renewal dates through license management. The lifecycle plan includes spare devices and parts; when a field switch fails, you need a spare that carries the same configuration.
Out of scope and limits
We manage SCADA systems; developing the SCADA software, programming PLCs, and writing tunnel safety scenarios are outside our scope, and the system manufacturer and the field integrator do them. Field work such as poles, brackets, and cable pulling is not ours either. The fiber line itself, meaning cable laying, splicing, and termination, is also outside our scope; we build the network on top of the line. We do not perform functional safety calculations or design for conformity with the tunnel directive. Toll collection software and bank integration belong to the software owner. We do not provide legal advice or certification. Which device meets the specification depends on the specification itself.
Related services
SIEM and log management, infrastructure and security monitoring, firewall and endpoint security, backup and disaster recovery, ARGE Cloud, and ARGE ZTNA are the separate pages for the work described here.
Technologies we use: industrial Ethernet switches · ring topology · VLAN · SNMP · NTP/PTP · IPsec · SD-WAN · ARGE ZTNA · SIEM · Windows Server · Linux
Frequently asked questions
Do you build the SCADA software or the tunnel ventilation scenario? We do not write SCADA software or program PLCs; the system manufacturer and the field integrator do that. We manage the servers, virtualization, databases, licenses, and monitoring that SCADA systems run on. We also build the network, security, and maintenance access.
Can we move all camera recordings to the cloud? In most setups, no. Primary recording stays at the center or in a regional center; incident video and the archive copy go to ARGE Cloud. The decision rests on a calculation with the number of cameras and the bit rate.
Can tunnel control run in the cloud? No. Safety control has to stay in the field and at the center, because the PLC must keep running the scenario even if the link to the center drops. The cloud is for backup, archive, reporting, and logs.
How long should we keep camera recordings? Law No. 6698 sets no fixed number of days; the test is the time the purpose requires. Unless your contract sets a period, you decide it as data controller, and we apply automatic deletion in the infrastructure.
Are motorways critical infrastructure under Law No. 7545? Transportation is among the critical infrastructure sectors set by the Cybersecurity Board. The Cybersecurity Presidency decides which individual operators count as critical infrastructure, so check with your own legal and compliance team and the Presidency's regulations.
A manufacturer needs remote access. Should we open a permanent VPN? You can use ARGE ZTNA instead. The manufacturer sees only the server you allow, every connection passes an identity and device check, and the session is recorded.
What do we look for when choosing an industrial switch? Operating temperature range, DIN rail mounting, PoE budget, ring redundancy protocol, and time synchronization. EN 50121-4, NEMA TS2, and IEC 61850-3 are indicators; we confirm in the model data sheet which one your specification asks for.
Can you review our existing network? Yes. With the IT Health Check we review your network, backups, and access in a scored report.
Who tracks the warranty and maintenance terms of the hardware? We do, through warranty and maintenance tracking; devices, terms, and renewal dates are kept in one calendar.